Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
36
STATION:#2
Select the next touchpad for which options are to be programmed (up to 15 touchpads)
5.16 Key Zones (Menu 15)
STATION:#0
Select the touchpad for which you want to program the panic key zones (0-15 touchpads).
NOTE Station #0 options are not used. Begin programming with Station #1.
KEY:UNUSED
Select the panic key to program. Although the display shows “KEY:UNUSED,” there is no
“UNUSED” key. You must select a panic key. Select 1 for the POL, 2 for the AUX key, and 3
for the FIRE key.
TYPE:
Select a zone type for the key you specified in the last step. Enter the number shown next to the
appropriate zone type in the following table.
NOTE 1. Undefined, Water, Heat, Cold, and Local zones will display as Auxiliary on the LCD. If
Local is selected, the panel will not dial out.
2. Do not select the “Unused” (option 14 or 15) zone type. It is intended for future use by the
factory. Use option 12 “Unused” if you need to program a zone that does not cause an alarm.
3. Option 6 was changed from “Gas” to “Supervisory” with Revision C of the 4734-2 control
software.
SIL.ALM:NO
If you select this option, alarms activated by this panic key will be reported to the central sta-
tion, but no audible alarm will sound.
REP DLY:NO
If you select this option, alarms activated by this panic key will be reported after a pro-
grammed delay time. The delay time is programmed in TIMERS (Menu 13).
BELL DLY:NO
Select this option to create a delay between the time an alarm condition is sensed by a zone of
the specified type and the time the alarm bell is sounded.
Table 13: Zone Types
Selection #
Zone Type
Selection #
Zone Type
Selection #
Zone Type
0 HOLDUP 6
SUPERVISORY
(formerly GAS)
11 LOCAL
1 FIRE 7 UNDEFINED 12 UNUSED
2 EMERGENCY 8 WATER 13 DOORBELL
3 PANIC 9 HEAT 14 UNUSED
4 BURGLARY 10 COLD 15 UNUSED