Model 4734 Access Control Expander Installation Manual (P/N 150807, Rev. A) Revised 5/98
7
In a large system or during heavy use, display response may be slower than normal.
For example, if 15 users are displaying Event Memory at the same time, the displays
will be slower than normal. Entry or exit delay displays may be updated less often
than once per second if the system is heavily loaded.
3.2.2 User Profiles
The 4734 controls system access through user profiles, which provide great flexibility while
simplifying access programming for end-users. User profiles are groups of options, time win-
dows, and areas that can be assigned to users. Up to 16 profiles can reside in a system. This dif-
fers from the 4724, which assigns options individually for each code.
For example, User Profile #1 could be created for card-only, Time Window #1, Area #1 users.
Any time a user with these access needs is added to the system, User Profile #1 is selected
when the code is added to the system. User profiles for users needing greater access to the sys-
tem can be created accordingly, making use of the 10 access options, (Arm, Disarm, Door,
Code2, Card-only, Bypass, Program, High Security, Time Windows, and Areas) available with
the system.
3.3 Area Control
An area is a part of a building that is being treated as a subsection of the total system. The
Model 4734 allows an installation to be divided into up to eight areas. The two levels of system
operation using areas are described below in Sections 3.3.1 and 3.3.2
3.3.1 Simple System
At this level of operation, the area programming is used only to divide system door access into
separately accessed areas. Codes and touchpads are programmed to determine which codes can
be used to gain door access at each touchpad. Arming and other functions operate at all stations
and apply to the entire system.
3.3.2 Split Arming
Split arming offers a high degree of independent operation for each area. Each area can be
independently armed and disarmed. Each area has its own entry and exit timer. Entry or exit
zones assigned to a particular area will be disabled during the entry or exit time for the area.
The programmed entry and exit times are shared by all areas.
Interior and instant operation are also controlled separately for each area. Each area has its own
interior zones and interior active status. Each area has its own instant status, which disables the
entry and exit timers for that area.
Code2 operation applies separately for each area. When the Code2 feature is activated, Code2
restricted access codes may disarm the area once. Normally Code2 restricted codes can never
disarm the system.
Each area can be armed and disarmed using only touchpads and codes that have been assigned
to the area.
3.3.3 Area Assignments
Each zone can be assigned to any one of the eight areas. Any number of zones may be assigned
to a particular area. Chime zones sound only at touchpads in the same area. Entry and exit
zones are also activated by area. There are separate entry/exit timers for each area.
Each code can be assigned to any or all of the eight areas. The code will only function at touch-
pads that are also assigned to the same area or areas.
Each touchpad can be assigned to one or more areas. More than one touchpad can be assigned
to each area. Each touchpad will display global system troubles and the status of any areas to
which it is assigned.
The Model 4180 Status Display Module can be programmed to activate speakers and bells for
alarm and trouble conditions that occur anywhere in the system or only for those that occur in
specific areas.
The only items that report by area are openings and closings.