Regency Excalibur EX-E33 Large Gas Insert Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Heizkörper Regency Excalibur EX-E33 Large Gas Insert herunter. Regency Excalibur EX-E33 Large Gas Insert User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 44
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4
918-513c
WARNING:
Improper installation, adjustment, alteration, service or
maintenance can cause injury, property damage, or loss
of life. Refer to this manual. For assistance or additional
information consult an authorized installer, service agency
or the gas supplier.
FOR YOUR SAFETY:
Do not store or use gasoline or other ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by an authorized
installer, service agency or the gas supplier.
FOR YOUR SAFETY:
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
04/12/11
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
E33 Gas Insert
Owners & Installation Manual
MODELS: E33-NG1 Natural Gas E33-LP1 Propane
Seitenansicht 0
1 2 3 4 5 6 ... 43 44

Inhaltsverzeichnis

Seite 1 - E33 Gas Insert

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4918-513cWARNING: Improper installation, adjustment, alteratio

Seite 2 - FPI GAS FIREPLACE INSERT

10E33 FPI Direct Vent Gas InsertINSTALLATIONMINIMUM CLEARANCES TO COMBUSTIBLES From Unit Side Walls * A 8" (203

Seite 3 - DIMENSIONS

E33 FPI Direct Vent Gas Insert11INSTALLATIONGAS CONNECTION 1) If the appliance is to be installed into an existing chimney system, thoroughly clean t

Seite 4 - TABLE OF CONTENTS

12E33 FPI Direct Vent Gas InsertINSTALLATIONOPTIONAL BRICK PANELOptional Brick Panel Set:Part # Description Qty Top (brick) panel 1 Ba

Seite 5 - SAFETY LABEL

E33 FPI Direct Vent Gas Insert13INSTALLATIONDiagram 1Installation of Brick Panels:1) Remove top louver and glass door if installed.2) Remove the log

Seite 6 - REQUIREMENTS

14E33 FPI Direct Vent Gas InsertINSTALLATIONGas Log Kit #340-930 contains the following:03-17 Bottom Log 03-18 Center Top Log03-19 Front Log03-20 Left

Seite 7

E33 FPI Direct Vent Gas Insert15INSTALLATION7) Align the bottom grooves of log 03-21 onto the right side of the grate and gently slide the log back u

Seite 8

16E33 FPI Direct Vent Gas InsertINSTALLATION03-1703-2003-2303-2203-18Diagram 1011) Place log 03-24 over log 03-23 and log 03-21 ensuring the pin hole

Seite 9

E33 FPI Direct Vent Gas Insert17INSTALLATIONEach Kit contains one LPG Conversion Kit and one DC Sparker Kit.LPG Conversion Kit Contains:Qty. Part # D

Seite 10 - INSTALLATION

18E33 FPI Direct Vent Gas InsertINSTALLATIONWARNING!Do not over tighten the screw. Recommended togrip the wrench by the short side.15) Using the Allen

Seite 11

E33 FPI Direct Vent Gas Insert19INSTALLATION31) Locate the ground lug at the receptical box, left of the unit.32) Connect one end of the supplied gree

Seite 12

2E33 FPI Direct Vent Gas InsertFPI GAS FIREPLACE INSERTTO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Insert by FPI.The

Seite 13

20E33 FPI Direct Vent Gas InsertINSTALLATIONDiagram 511) Push the FPI logo plate into the two holes in the bottom left corner of the faceplate.10) Att

Seite 14

E33 FPI Direct Vent Gas Insert21INSTALLATIONCONTEMPORARY FACEPLATE &DOOR FRAME1) Bring the faceplate up in front of the unit and connect the red

Seite 15

22E33 FPI Direct Vent Gas InsertINSTALLATION6) Place 2 screws through the screw holes on the hinge and place a spacer over each screw.7) Secure the

Seite 16

E33 FPI Direct Vent Gas Insert23INSTALLATION1) Attach the inner faceplate panel to the insert body using 4 screws in the locations shown below.Diagra

Seite 17

24E33 FPI Direct Vent Gas Insert46-15/32” (1180)42-7/16” (1078mm)26-3/4” (678mm)28.11/16” (729mm)33-5/16” (846mm)18-7/16” (467mm)INSTALLATIONDiagram 9

Seite 18

E33 FPI Direct Vent Gas Insert25INSTALLATIONThe standard fl ush door comes with a black frame. To install the frame, simply hook the top door fl ange on

Seite 19

26E33 FPI Direct Vent Gas InsertINSTALLATION1) Align the left side Faceplate Trim Bracket with the Firebox Flange and secure using 2 screws as shown

Seite 20

E33 FPI Direct Vent Gas Insert27INSTALLATION1) Remove the rivets from the surround by pulling off the hoseclamp (located at the backside of surround)

Seite 21

28E33 FPI Direct Vent Gas InsertINSTALLATIONWIRING DIAGRAMSThis heater does not require a 120V A.C. supply for operation. However, a 120V A.C. power

Seite 22

E33 FPI Direct Vent Gas Insert29INSTALLATIONUse the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty.The rem

Seite 23

E33 FPI Direct Vent Gas Insert346-15/32” (1180)42-7/16” (1078mm)26-3/4” (678mm)28.11/16” (729mm)33-5/16” (846mm)18-7/16” (467mm)10-11/16”(271mm)DIMENS

Seite 24

30E33 FPI Direct Vent Gas Insert30OPERATING INSTRUCTIONSIMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "OFF" unless i

Seite 25

Regency Gas Fireplace31OPERATING INSTRUCTIONSCOPY OF LIGHTING INSTRUCTION PLATEAUTOMATIC CONVECTION FAN OPERATIONThe fan operates automatically. Turn

Seite 26

32E33 FPI Direct Vent Gas InsertMAINTENANCEGENERAL VENT MAINTENANCEConduct an inspection of the venting system semi-annually. Recommended areas to ins

Seite 27

E33 FPI Direct Vent Gas Insert33MAINTENANCEFAN MAINTENANCEIf your fan requires maintenance or replacement, access to the fan is through the plate on t

Seite 28

34E33 FPI Direct Vent Gas InsertMAINTENANCE11) Disconnect the inlet gas line.12) Unplug the black and red wires at the valve. Undo the 2 TP wires at t

Seite 29

E33 FPI Direct Vent Gas Insert35PARTS LISTMAIN ASSEMBLY Part # Description 1) 340-038 Fan Access Plate2) 340-

Seite 30 - OPERATING INSTRUCTIONS

36E33 FPI Direct Vent Gas InsertPARTS LISTBURNER & LOG ASSEMBLY Part # Description

Seite 31

E33 FPI Direct Vent Gas Insert37PARTS LIST838485868788888888899090FULL SCREEN FRONT Part # Description

Seite 32 - MAINTENANCE

38E33 FPI Direct Vent Gas InsertPARTS LISTFACEPLATES, TRIMS AND HEARTHS Part # Description

Seite 33

E33 FPI Direct Vent Gas Insert39PARTS LISTCONTEMPORARY FACEPLATE & DOOR FRAME Part # Description

Seite 34

4E33 FPI Direct Vent Gas Insert4TABLE OF CONTENTSExcalibur Screen Doors ...27Excalibur Accent Kit ...

Seite 35 - PARTS LIST

40E33 FPI Direct Vent Gas InsertPARTS LISTLOW PROFILE FACEPLATE Part # Description1) * Backplate Assembly2) * Bo

Seite 36

E33 FPI Direct Vent Gas Insert41NOTES

Seite 37

42E33 FPI Direct Vent Gas InsertNOTES

Seite 38

E33 FPI Direct Vent Gas Insert43WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Qua

Seite 39

Printed in CanadaRegency and Excalibur are trademarks of FPI Fireplace Products International Ltd. © Copyright 2010, FPI Fireplace Products Internatio

Seite 40

E33 FPI Direct Vent Gas Insert5SAFETY LABELThis is a copy of the labels that accompany each E33 Gas Insert. We have printed a copy of the contents her

Seite 41

6E33 FPI Direct Vent Gas InsertREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requirements

Seite 42

E33 FPI Direct Vent Gas Insert7INSTALLATION4) See general construction and assembly instructions. This appliance may only be installed in a vented, n

Seite 43 - WARRANTY

8E33 FPI Direct Vent Gas InsertINSTALLATIONGAS PRESSURE TESTINGThe appliance must be isolated from the gas supply piping system by closing its individ

Seite 44 - warranty online

E33 FPI Direct Vent Gas Insert9INSTALLATIONMATERIALS REQUIREDNo electrical power supply is required for the gas control to operate. A 120 Volt AC pow

Kommentare zu diesen Handbüchern

Keine Kommentare