WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapours and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-525b
MODELS: P90-NG1 Natural Gas P90-LP1 Propane
06/14/10
P90 Zero Clearance Direct Vent Gas Fireplace
Owners &
Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.excalibur- re.com
Seitenansicht 0
1 2 3 4 5 6 ... 55 56

Inhaltsverzeichnis

Seite 1 - Installation Manual

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Seite 2 - To the New Owner:

10Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONSide Wall Clearance 6-1/2" (165mm)Horizontal Vent Clearances Top 2-1/2&quo

Seite 3

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace11INSTALLATION19-1/4"(489mm)including standoffs10-7/8"(276mm)49-7/8"(1267mm)70-1

Seite 4 - TABLE OF CONTENTS

12Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONFireplaceStandNo hearth isrequired whenthe unit is raised3" (76mm) off ofthe

Seite 5 - DIMENSIONS

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace13INSTALLATIONVENTING INTRODUCTIONThe P90 uses the "balanced fl ue" technology C

Seite 6 - SAFETY LABEL

14Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONVENTINGFPI Direct Vent System (Flex) Horizontal Terminations OnlyThese venting s

Seite 7 - REQUIREMENTS

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace15INSTALLATIONEXTERIOR VENT TERMINATION LOCATIONSMinimum Clearance RequirementsCanada1USA2A Cle

Seite 8

16Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacturers may not b

Seite 9

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace17DescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Amerivent DirectM

Seite 10 - INSTALLATION

18Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONAdjustable Length 3”-10”-Galvanized N/A N/A 5DAL TC-5DLTAdjustable Length 3”-10”-

Seite 11

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace19INSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™Metal-Fab™Sure SealICC Excel

Seite 12

2Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Excalibur® Gas Firep

Seite 13

20Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRigid Pipe AdaptorPipe LengthVerticalTerminalStorm CollarFlashing943 or 943SCeili

Seite 14

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace21INSTALLATIONHorizontal & Vertical Terminations for 5" x 8" Venting

Seite 15

22Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONSFPI DIRECT VENT SYSTEM

Seite 16

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace23INSTALLATIONPlease note that all vertical measurements are taken from the base of the unit ex

Seite 17

24Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONHorizontal Venting with Two (2) 90o ElbowsHorizontal Venting with Three (3) 90o E

Seite 18

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace25INSTALLATIONVertical Venting with Two (2) 90o ElbowsVertical Venting with Three (3) 90o Elbow

Seite 19

26Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONDiagram 46) The arrow on the vent cap should be pointing up. Insure that the 1-1

Seite 20

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace27INSTALLATION2) Set the gas appliance in its desired location. Drop a plumb bob down from the

Seite 21

28Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATION4) Separate the 2 halves of the wall thimble and securely fasten the one with th

Seite 22

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace29INSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply pipin

Seite 23

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace3INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALEThis Excalibur® product has been tes

Seite 24

30Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONCONVERSION KIT #791-969 FROM NG TO LP THIS CONVERSION MUST BE DONE BY A QUALIFIED

Seite 25

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace31INSTALLATION17) Reverse steps 4) to 2).18) Attach clear label "This unit has been conv

Seite 26

32Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATION9) Install the plastic bushing over the outside of the hole.10) Attach the grou

Seite 27

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace33INSTALLATION5) Locate the ground lug at the receptical box, left of the unit.Installer Notic

Seite 28

34Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATION1) Open the bottom louver door. Loosen the 2 screws holding the Burner ON/OFF sw

Seite 29

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace35INSTALLATIONLOG SET INSTALLATIONNotchBracketBracket02-5102-7502-513) Place the Log 02-75 on

Seite 30

36Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRear Bracket02-5502-7502-537) Place the bottom left front edge of Log 02-55 aga

Seite 31

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace37INSTALLATIONLog IndentationPhoto shows rear grate tab. Log 02-51 was removed to show the posi

Seite 32

38Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONPlace embers in these 3 locations on the burner tray.02-5002-5502-7502-5302-5102-

Seite 33

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace39INSTALLATIONDoorFlangeOPTIONAL SCREEN DOOR 1) Attach door bracket to side using 2 screws.GLA

Seite 34

4Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace4TABLE OF CONTENTSGlass Door Installation ...39Ar

Seite 35

40Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONACCENT KIT INSTALLATION2) Take the hoseclamps and put them over the back of each

Seite 36

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace41INSTALLATIONOption 1: REMOTE CONTROLUse the Excalibur® Remote Control Kit approved for this

Seite 37

42Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONWIRING DIAGRAMS Caution: Ensure that the wires do not touch any hot surfaces and

Seite 38

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace43INSTALLATIONFor PROPANE Units and Units Equipped with DC Spark Boxes**For installation of the

Seite 39

44Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace44Regency Gas Fireplace44OPERATING INSTRUCTIONS OPERATING INSTRUCTIONSLIGHTING PROCEDUREIMPOR

Seite 40

Regency Gas Fireplace45OPERATING INSTRUCTIONSCOPY OF THE LIGHTING PLATE INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCESIt is possible that you

Seite 41

46Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceExcalibur® P90 Zero Clearance Direct Vent Gas Fireplace46MAINTENANCE MAINTENANCEGLASS GASKET

Seite 42

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace47MAINTENANCE5) Connect fan ground cable to ground lug. Refer to wiring diagram.6) Slide the

Seite 43

48Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceMAINTENANCE12) Undo the pilot tube from the valve with a 7/16" wrench.13) Undo the quic

Seite 44 - Open - Short Blue

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace4949Excalibur® P90 Zero Clearance Direct Vent Gas FireplacePARTS LISTPARTS LISTMAIN ASSEMBLY

Seite 45 - OPERATING INSTRUCTIONS

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace5DIMENSIONSBAHIGCFDEUnit Dimensions Description P90A Front Firebox Width 42” (1067mm)B Rear Fir

Seite 46 - MAINTENANCE MAINTENANCE

50Excalibur® P90 Zero Clearance Direct Vent Gas FireplacePARTS LIST61384347484232646119736498102642236152023242125242325108109HEAT RELEASE DUCT KITFAN

Seite 47 - MAINTENANCE

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace51PARTS LISTAETHTPTPTHTPTHAIRINAIRINOOTLIP52695853578283568579757668686766BURNER ASSEMBLY &

Seite 48

52Excalibur® P90 Zero Clearance Direct Vent Gas FireplacePARTS LIST164141156FLUSH DOOR132135136148148158SINGLE DOOR151DOUBLE DOORS16114616215516816715

Seite 49 - PARTS LISTPARTS LIST

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace53NOTES

Seite 50 - PARTS LIST

54Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceNOTES

Seite 51

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace5555Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceWARRANTYWARRANTYExcalibur Fireplace

Seite 52

56Installer: Please complete the following informationDealer Name & Address: _____________________________________________________________________

Seite 53 - Excalibur

6Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceSAFETY LABELThis is a copy of the label that accompanies each P90 Zero Clearance Direct Vent G

Seite 54

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace7REQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the followin

Seite 55 - WARRANTYWARRANTY

8Excalibur® P90 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe P90-NG1 or P90-LP1 Direct Vent Firep

Seite 56

Excalibur® P90 Zero Clearance Direct Vent Gas Fireplace9INSTALLATIONINSTALLATION CHECKLIST1) Locate appliance, refer to the following sections: a)

Kommentare zu diesen Handbüchern

Keine Kommentare