Regency 4720 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Mobiltelefone Regency 4720 herunter. Regency 4720 User`s manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 35
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
User's Manual Page i
Table of Contents
Section 1. Introduction....................................................................................... 1
Section 2. System Overview...............................................................................2
Monitoring Capabilities ..................................................................... 2
Intrusion...................................................................................... 2
Fire.............................................................................................. 2
Equipment Tampering and Auxiliary.......................................... 2
Access Codes ..................................................................................... 3
Installer’s Code (Code 0)............................................................ 3
Main User’s Code (Code 1) ........................................................ 3
Primary Access Codes (Codes 2-98)........................................... 4
High Security Door Access Code (Optional).............................. 4
Touchpad Descriptions ...................................................................... 4
Models 4660B and 4660C........................................................... 4
Model 4205 Slimline Touchpad (not UL listed).......................... 5
System Status Lights .......................................................................... 6
Touchpad Buttons .............................................................................. 7
Section 3. Using Your Model 4720 Security System........................................ 9
Arming Your System.......................................................................... 9
Disarming Your System ..................................................................... 9
Resolving Not Ready Conditions..................................................... 10
Viewing Alarms and Alarm Memory ............................................... 10
Viewing Trouble and Supervisory Conditions .......................... 10
Viewing Alarm Memory ............................................................ 10
Silencing Trouble Sounds ................................................................ 11
Bypassing Zones .............................................................................. 11
Bypassing a Zone...................................................................... 11
Reinstating a Bypassed Zone .................................................... 11
Bypassing or Reinstating an Armed System.............................. 12
Activating Chime Sounds................................................................. 12
Sending Silent Duress (Hold Up) Alarms ........................................ 12
Activating Doorstrikes ..................................................................... 12
Activating High Security Doorstrikes .............................................. 13
Technical Manuals Online! - http://www.tech-man.com
Seitenansicht 0
1 2 3 4 5 6 ... 34 35

Inhaltsverzeichnis

Seite 1 - Table of Contents

User's Manual Page iTable of ContentsSection 1. Introduction...

Seite 2

Model 4720 Commercial Security SystemPage 8 User's ManualTouchpad buttons continued.Button DescriptionControls the telephone functions. It will

Seite 3 - Introduction

User's Manual Page 9Section 3.Using Your Model 4720 Security SystemThe following is an operating guide for each of your Model 4720 securitysystem

Seite 4 - System Overview

Model 4720 Commercial Security SystemPage 10 User's ManualThe warning tone will stop as soon as you enter the first digit of your accesscode, al

Seite 5 - Access Codes

Section 3. Using Your Model 4720 Security SystemUser's Manual Page 11number and location of any alarms that have occurred since the last time th

Seite 6 - Touchpad Descriptions

Model 4720 Commercial Security SystemPage 12 User's ManualThe zone is now reinstated. Repeat steps for all zones that you want toreinstate.Bypass

Seite 7 - R E G E N C Y

Section 3. Using Your Model 4720 Security SystemUser's Manual Page 13Activating High Security DoorstrikesUse these steps if the high security ac

Seite 8 - System Status Lights

Model 4720 Commercial Security SystemPage 14 User's ManualListen-only Communications With One Intercom1. Press the number of the intercom station

Seite 9 - Touchpad Buttons

Section 3. Using Your Model 4720 Security SystemUser's Manual Page 15To: StepsTransfer a call to anothertouchpad1. Answer an incoming call by pr

Seite 10 - Page 8 User's Manual

Model 4720 Commercial Security SystemPage 16 User's ManualTo: Steps The phone number is now in memory anda call has been placed to the phonenumbe

Seite 11 - Section 3

Section 3. Using Your Model 4720 Security SystemUser's Manual Page 17Programming Your 4720 Security SystemYour security dealer or installer will

Seite 12

Model 4720 Commercial Security SystemPage ii User's ManualIntercom Operation (Optional)...

Seite 13 - Bypassing Zones

Model 4720 Commercial Security SystemPage 18 User's ManualResetting the DateIf your system includes an on-site printer, the display will prompt y

Seite 14 - Activating Doorstrikes

Section 3. Using Your Model 4720 Security SystemUser's Manual Page 19Changing Your Access CodeAccess codes are 3 to 6 digits in length. You mus

Seite 15 - Intercom Operation (Optional)

Model 4720 Commercial Security SystemPage 20 User's ManualTesting Your 4000 Security SystemIMPORTANTWeekly tests are recommended to ensureproper

Seite 16

User's Manual Page 21Section 4.In Case of TroubleAC Power FailuresDuring brief power outages in your building, your security system willfunction

Seite 17

Model 4720 Commercial Security SystemPage 22 User's ManualWhen an alarm or trouble condition occurs, the touchpad displays ALARM,TROUBLE, or in s

Seite 18 - Page 16 User's Manual

Section 4. In Case of TroubleUser's Manual Page 23Beeper SoundsThe following table describes other audible signals:Type Sound DescriptionAlarms

Seite 19

Page 24 User's ManualSection 5.System MessagesTrouble MessagesYour security system is designed to provide you with many years of reliabletrouble-

Seite 20 - , enter the ID number of

Section 5. System MessagesUser's Manual Page 25Error MessagesIf operation or programming errors occur, the LCD will display thefollowing message

Seite 21

Model 4720 Commercial Security SystemPage 26 User's ManualALARM monitoring are in alarm.NOT READY One or more zones are in a Not Ready condition

Seite 22 - MUTE MUTE to silence

User's Manual Page 27System DataKeep the following information CONFIDENTIAL andstored in a safe place.System Installation company: _____________

Seite 23 - In Case of Trouble

User's Manual Page 1Section 1.IntroductionCongratulations! You have just purchased a Regency 4000 Series SecuritySystem; one of the most sophist

Seite 24 - Audible Alarms

Model 4720 Commercial Security SystemPage 28 User's ManualYour system zone locations are:1. ____________________________ 41. ____________________

Seite 25 - Beeper Sounds

System DataUser's Manual Page 29Your access code assignments are:# Access Code Options Assigned To1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

Seite 26 - System Messages

Model 4720 Commercial Security SystemPage 30 User's Manual# Access Code Options Assigned To34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51

Seite 27 - LCD Displays

System DataUser's Manual Page 31# Access Code Options Assigned To67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93

Seite 28 - Page 26 User's Manual

Limited WarrantyThe manufacturer warrants that the products of its manufacture shall be freefrom defects in materials or workmanship for one year from

Seite 29 - System Data

Part Number 150480 R E G E N C YRevised April 1995 7550 Meridian CircleMaple Grove, Minnesota 55369-4927Technical Manuals Online! - http://www.tech-ma

Seite 30 - Page 28 User's Manual

Page 2 User's ManualSection 2.System OverviewMonitoring CapabilitiesYour Model 4720 security system is active 24 hours a day, monitoring forfire,

Seite 31 - User's Manual Page 29

Section 2. System OverviewUser's Manual Page 3Access CodesAn access code is a confidential number, 3 to 6 digits in length. You enterthis code

Seite 32 - Page 30 User's Manual

Model 4720 Commercial Security SystemPage 4 User's ManualPrimary Access Codes (Codes 2-98)Up to 98 primary access codes can be provided by your s

Seite 33 - User's Manual Page 31

Section 2. System OverviewUser's Manual Page 5R E G E N C YMODEL 4660C12 34567890TESTSTATINTBYPSCODE2DLYICOMPOLCLRTELFIREMUTEAUXCHMMEMREADYARMED

Seite 34

Model 4720 Commercial Security SystemPage 6 User's ManualSystem Status LightsThe lights on the top left of the touchpad provide information about

Seite 35

Section 2. System OverviewUser's Manual Page 7Touchpad ButtonsButtons always visible on the touchpad are for frequently used functionssuch as ar

Kommentare zu diesen Handbüchern

Keine Kommentare