Regency Sunrise E33S Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Kamine Regency Sunrise E33S herunter. Regency Sunrise E33S User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 32
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-747
E33 Sunrise
Gas Insert
02/16/09
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
MODELS: E33S-NG1 Natural Gas E33S-LP1 Propane
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - Gas Insert

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Seite 2 - FPI GAS FIREPLACE INSERT

Regency® E33S-1 Sunrise Gas Insert 10INSTALLATIONINSTALLATIONVENTINGTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUE

Seite 3 - TABLE OF CONTENTS

Regency® E33S-1 Sunrise Gas Insert 11INSTALLATIONINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping syste

Seite 4 - SAFETY LABEL

Regency® E33S-1 Sunrise Gas Insert 12INSTALLATIONINSTALLATIONCONVERSION KIT #434-969FROM NG TO LP

Seite 5 - REQUIREMENTS

Regency® E33S-1 Sunrise Gas Insert 13INSTALLATIONINSTALLATION

Seite 6 - UNIT DIMENSIONS

Regency® E33S-1 Sunrise Gas Insert 14INSTALLATIONINSTALLATION

Seite 7

Regency® E33S-1 Sunrise Gas Insert 15INSTALLATIONWIRING DIAGRAMSThis heater does not require a 120V A.C. supply for operation. However, a 120V A.C.

Seite 8

Regency® E33S-1 Sunrise Gas Insert 16INSTALLATIONUse the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty.Th

Seite 9

Regency® E33S-1 Sunrise Gas Insert 17INSTALLATIONGLASS DOOR INSTALLATIONINSTALLATIONTo install the glass door, simply hook the top door fl ange onto t

Seite 10 - INSTALLATION

Regency® E33S-1 Sunrise Gas Insert 18INSTALLATIONINSTALLATIONCONTEMPORARY FACEPLATE &DOOR FRAME INSTALLATION1) Bring the faceplate up in front of

Seite 11

Regency® E33S-1 Sunrise Gas Insert 19INSTALLATION6) Place 2 screws through the screw holes on the hinge and place a spacer over each screw.7) Secur

Seite 12

Regency® E33S-1 Sunrise Gas Insert 2FPI GAS FIREPLACE INSERTTO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Insert by FP

Seite 13

Regency® E33S-1 Sunrise Gas Insert 20INSTALLATIONOPTIONAL HEARTH TRIMINSTALLATIONThe Hearth Trim is an option that can be used to fi nish off the insta

Seite 14

Regency® E33S-1 Sunrise Gas Insert 21OPERATIONOPERATING INSTRUCTIONSIMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "OFF&q

Seite 15

Regency® E33S-1 Sunrise Gas Insert 22OPERATIONOPERATING INSTRUCTIONSCOPY OF LIGHTING INSTRUCTION PLATEAUTOMATIC CONVECTION FAN OPERATIONThe fan opera

Seite 16

Regency® E33S-1 Sunrise Gas Insert 23MAINTENANCEMAINTENANCEGENERAL VENT MAINTENANCEConduct an inspection of the venting system semi-annually. Recomme

Seite 17

Regency® E33S-1 Sunrise Gas Insert 24MAINTENANCEMAINTENANCEVALVE TRAY REPLACEMENT1) Turn the unit off and allow it to cool down to room temperature.2

Seite 18

Regency® E33S-1 Sunrise Gas Insert 25MAINTENANCE9) Remove the base cover by lifting up from the back and maneover out.Base Cover10) Disconnect the O

Seite 19

Regency® E33S-1 Sunrise Gas Insert 26MAINTENANCEFAN REPLACEMENT6) Remove the back shield by undoing the 2 screws shown.9) Remove the base cover by

Seite 20

Regency® E33S-1 Sunrise Gas Insert 27MAINTENANCE10) Remove the fan access plate by undoing the 12 screws shown.11) Remove the 2 screws that hold the

Seite 21 - OPERATING INSTRUCTIONS

Regency® E33S-1 Sunrise Gas Insert 28PARTS LISTPARTS LISTMAIN ASSEMBLY Part # Description 1) 340-038 Fan Acces

Seite 22

Regency® E33S-1 Sunrise Gas Insert 29PARTS LISTPARTS LISTCONTEMPORARY FACEPLATE & DOOR FRAME Part # Description

Seite 23 - MAINTENANCE

Regency® E33S-1 Sunrise Gas Insert 3TABLE OF CONTENTSSAFETY LABELCopy of the Safety Label ...4REQUIREMENT

Seite 24

Regency® E33S-1 Sunrise Gas Insert 30NOTES

Seite 25

Regency® E33S-1 Sunrise Gas Insert 31WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our intern

Seite 26

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Seite 27

Regency® E33S-1 Sunrise Gas Insert 4INSTALLATIONSAFETY LABELThis is a copy of the safety label that accompanies the E33 SunriseTM Gas Insert. We have

Seite 28 - PARTS LIST

Regency® E33S-1 Sunrise Gas Insert 5INSTALLATIONREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following addit

Seite 29

Regency® E33S-1 Sunrise Gas Insert 6INSTALLATIONUNIT DIMENSIONS

Seite 30 - E33S-1 Sunrise Gas Insert

Regency® E33S-1 Sunrise Gas Insert 7INSTALLATIONINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe FPI Gas Insert must be installed in accord-a

Seite 31 - WARRANTY

Regency® E33S-1 Sunrise Gas Insert 8INSTALLATIONINSTALLATION11) Due to high temperatures, the appliance should be located out of high traffi c areas an

Seite 32

Regency® E33S-1 Sunrise Gas Insert 9INSTALLATIONINSTALLATIONMINIMUM CLEARANCES TO COMBUSTIBLES From Unit Side Walls

Kommentare zu diesen Handbüchern

Keine Kommentare