WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-747b
E33 Sunrise
Gas Insert
01/05/10
Owners &
Installation Manual
www.regency- re.com
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
MODELS: E33S-NG1 Natural Gas E33S-LP1 Propane
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - Gas Insert

WARNING: If the information in these instructions are not followed exactly, a fi re or explosion may result causing property damage, personal injury

Seite 2 - FPI GAS FIREPLACE INSERT

Regency® E33S-1 Sunrise Gas Insert 10INSTALLATIONINSTALLATIONVENTINGTHE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUE

Seite 3 - TABLE OF CONTENTS

Regency® E33S-1 Sunrise Gas Insert 11INSTALLATIONINSTALLATIONGAS PIPE PRESSURE TESTINGThe appliance must be isolated from the gas supply piping syste

Seite 4 - SAFETY LABEL

Regency® E33S-1 Sunrise Gas Insert 12INSTALLATION1) Turn off the gas supply.2) Remove the glass door. E33S only: a) Remove the 2 screws at

Seite 5 - REQUIREMENTS

Regency® E33S-1 Sunrise Gas Insert 13INSTALLATIONINSTALLATION7) Remove burner orifi ce with a 1/2" wrench and discard.8) Install the new LP bur

Seite 6 - UNIT DIMENSIONS

Regency® E33S-1 Sunrise Gas Insert 14INSTALLATIONInstallation of the DC Sparker:1) Locate the Piezo Ignitor situated at the side of valve.Piezo Ignit

Seite 7

Regency® E33S-1 Sunrise Gas Insert 15INSTALLATION14) Tie up the loose wire with the wire clip.13) Find a location which is not too hot and is easy

Seite 8

Regency® E33S-1 Sunrise Gas Insert 16INSTALLATIONWIRING DIAGRAMSThis heater does not require a 120V A.C. supply for operation. However, a 120V A.C. p

Seite 9

Regency® E33S-1 Sunrise Gas Insert 17INSTALLATIONUse the FPI Remote Control Kit approved for this unit. Use of other systems may void your warranty.T

Seite 10 - INSTALLATION

Regency® E33S-1 Sunrise Gas Insert 18INSTALLATIONINSTALLATIONOPTIONAL REFLECTIVE PANEL INSTALLATIONBefore installation, panels must be handled and cle

Seite 11

Regency® E33S-1 Sunrise Gas Insert 19INSTALLATIONINSTALLATION10) After the top panel has been secured - install the back panel. The back pane

Seite 12

Regency® E33S-1 Sunrise Gas Insert 2FPI GAS FIREPLACE INSERTTO THE NEW OWNERCongratulations! You are the owner of a state-of-the-art Gas Insert by FP

Seite 13

Regency® E33S-1 Sunrise Gas Insert 20INSTALLATIONINSTALLATION13) Re-install fi rebox base.14) Re-install pilot assembly cover.15) Re-install burner.16

Seite 14 - Red o-ring visible

Regency® E33S-1 Sunrise Gas Insert 21INSTALLATIONGLASS DOOR INSTALLATIONTo install the glass door, simply hook the top door fl ange onto the top of th

Seite 15

Regency® E33S-1 Sunrise Gas Insert 22INSTALLATIONCONTEMPORARY FACEPLATE &DOOR FRAME INSTALLATION1) Bring the faceplate up in front of the unit an

Seite 16

Regency® E33S-1 Sunrise Gas Insert 23INSTALLATION6) Place 2 screws through the screw holes on the hinge and place a spacer over each screw.7) Secur

Seite 17

Regency® E33S-1 Sunrise Gas Insert 24INSTALLATION1) Attach the inner faceplate panel to the insert body using 4 screws in the locations shown below.D

Seite 18

Regency® E33S-1 Sunrise Gas Insert 25INSTALLATIONDiagram 9Outer faceplateInner faceplatepanel pinsDiagram 108) Attach the bottom louver to the 2 hin

Seite 19

Regency® E33S-1 Sunrise Gas Insert 26INSTALLATIONOPTIONAL HEARTH TRIMINSTALLATIONThe Hearth Trim is an option that can be used to fi nish off the insta

Seite 20

Regency® E33S-1 Sunrise Gas Insert 27OPERATIONOPERATING INSTRUCTIONSIMPORTANT: Gas on/off knob cannot be turned from "PILOT" to "OFF&q

Seite 21

Regency® E33S-1 Sunrise Gas Insert 28OPERATIONOPERATING INSTRUCTIONSCOPY OF LIGHTING INSTRUCTION PLATEAUTOMATIC CONVECTION FAN OPERATIONThe fan opera

Seite 22

Regency® E33S-1 Sunrise Gas Insert 29MAINTENANCEMAINTENANCEGENERAL VENT MAINTENANCEConduct an inspection of the venting system semi-annually. Recomme

Seite 23

Regency® E33S-1 Sunrise Gas Insert 3TABLE OF CONTENTSSAFETY LABELCopy of Safety Decal ...4REQUIREME

Seite 24

Regency® E33S-1 Sunrise Gas Insert 30MAINTENANCEMAINTENANCEVALVE TRAY REPLACEMENT1) Turn the unit off and allow it to cool down to room temperature.2

Seite 25

Regency® E33S-1 Sunrise Gas Insert 31MAINTENANCE8) Remove the base cover by lifting up from the back and maneover out.Base Cover9) Disconnect the O

Seite 26

Regency® E33S-1 Sunrise Gas Insert 32MAINTENANCEFAN REPLACEMENT8) Remove the base cover by lifting up from the back and maneover out.6) Remove the b

Seite 27 - OPERATING INSTRUCTIONS

Regency® E33S-1 Sunrise Gas Insert 33MAINTENANCE9) Remove the fan access plate by undoing the 12 screws shown.10) Remove the 2 screws that hold the

Seite 28

Regency® E33S-1 Sunrise Gas Insert 34PARTS LIST1394948217181951378AIRINAIRINAETHTPTPTHTPTHOOTLIP56575982525554676679PARTS LISTMAIN ASSEMBLY Pa

Seite 29 - MAINTENANCE

Regency® E33S-1 Sunrise Gas Insert 35PARTS LISTPARTS LISTACCESSORIES Part # Description

Seite 30

Regency® E33S-1 Sunrise Gas Insert 36PARTS LISTLOW PROFILE FACEPLATE Part # Description1) * Backplate Assembly2) *

Seite 31

Regency® E33S-1 Sunrise Gas Insert 37NOTES

Seite 32

Regency® E33S-1 Sunrise Gas Insert 38NOTES

Seite 33

Regency® E33S-1 Sunrise Gas Insert 39WARRANTYRegency Fireplace Products are designed with reliability and simplicity in mind. In addition, our intern

Seite 34 - PARTS LIST

Regency® E33S-1 Sunrise Gas Insert 4INSTALLATIONSAFETY LABELThis is a copy of the safety label that accompanies the E33 SunriseTM Gas Insert. We have

Seite 35

Regency® E33S-1 Sunrise Gas Insert 40Installer: Please complete the following informationDealer Name & Address: __________________________________

Seite 36

Regency® E33S-1 Sunrise Gas Insert 5INSTALLATIONREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following addit

Seite 37

Regency® E33S-1 Sunrise Gas Insert 6INSTALLATIONUNIT DIMENSIONS32-1/8” (816mm)47-1/2” (1207mm)11-3/8”(290mm)1-1/8”(28mm)2-7/8”(72mm)16-1/2” (419mm)16-

Seite 38 - E33S-1 Sunrise Gas Insert

Regency® E33S-1 Sunrise Gas Insert 7INSTALLATIONINSTALLATIONIMPORTANT MESSAGE SAVE THESE INSTRUCTIONSThe FPI Gas Insert must be installed in accord-a

Seite 39 - WARRANTY

Regency® E33S-1 Sunrise Gas Insert 8INSTALLATIONINSTALLATION11) Due to high temperatures, the appliance should be located out of high traffi c areas an

Seite 40

Regency® E33S-1 Sunrise Gas Insert 9INSTALLATIONINSTALLATIONMINIMUM CLEARANCES TO COMBUSTIBLES From Unit Side Walls