Regency C34-LP2 Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Herde Regency C34-LP2 herunter. Regency C34-LP2 Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 48
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-523b
MODELS: P42-NG4 Natural Gas P42-LP4 Propane
P42 Gas Fireplace
WARNING:
If the information in these instructions are not followed exactly,
a re or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other ammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a quali ed
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the re department.
Owners &
Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
08/24/10
www.regency- re.com
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - P42 Gas Fireplace

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4918-523bMODELS: P42-NG4 Natural Gas P42-LP4 PropaneP42 Gas

Seite 2 - To the New Owner:

10Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONMANTEL LEG CLEARANCESCombustible mantel leg clearances as per diagram below:MANTE

Seite 3

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace11INSTALLATIONPosition of Top Facing Supportfor material depth of 3/4” to 1-1/2"Top Facing

Seite 4 - TABLE OF CONTENTS

12Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONEXTERIOR VENT TERMINATION REQUIREMENTSMinimum Clearance RequirementsCanada1USA2A

Seite 5 - SAFETY LABEL

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace13INSTALLATION6-7/8"(173mm) dia.Flue pipe4" (102mm)dia. flue pipeTermination CapPart

Seite 6 - REQUIREMENTS

14Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHARTComponents from different Manufacture

Seite 7

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace15INSTALLATIONDescriptionSimpsonDirect Vent Pro®SelkirkDirect Temp™American MetalProducts®Ameri

Seite 8

16Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRigid Pipe Adaptor(Part# 510-994)Pipe LengthVerticalTerminalStorm CollarPart # 95

Seite 9

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace17INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONSREGENCY® DIRECT VENT SY

Seite 10 - INSTALLATION

18Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - HORIZONTAL TERMINATIONSREGENCY® DIRECT VENT SY

Seite 11

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace19INSTALLATIONRIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS(Propane & Natural Gas

Seite 12

2Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceTo the New Owner:Congratulations! You are the owner of a state-of-the-art Gas Fireplace by FI

Seite 13

20Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONThe P42 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft (3.7m) ho

Seite 14

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace21INSTALLATIONFlex LinerExhaustFlueA maximumof two certifiedjoiner kitsmay be usedper length.#9

Seite 15

22Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONVENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for bothR

Seite 16

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace23INSTALLATIONBelow Grade InstallationIf the Snorkel Termination must be installed below grade,

Seite 17

24Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION1) Maintain the 1-1/4"(32mm) clearances (air spaces) to combustibles when p

Seite 18

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace25INSTALLATION3) Assemble the vent assembly by applying Mill Pac to the 4"(100mm) inner c

Seite 19

26Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONGAS LINE INSTALLATIONThe gas line can be brought through either the right or the

Seite 20

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace27INSTALLATIONAERATION ADJUSTMENTThe aeration adjustment gears are located on the valve mountin

Seite 21

28Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONLOG SET INSTALLATIONunits.5) Place the front logs in the unit, aligning the hole

Seite 22

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace29INSTALLATIONDiagram 1Diagram 3STANDARD FLUSH DOORThe standard fl ush door comes with a black f

Seite 23

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace3INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALEThis Regency® product has been teste

Seite 24

30Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONBAY LOUVERS1) Install top louver by sliding the two bracket clips into the brack

Seite 25

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace31INSTALLATIONFULL SCREEN DOORS2) Remove the Screen Doors from the Full Screen Door Frame by f

Seite 26

32Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONInnerCut-OutsBottom Flange NOTE: Should the fi nished wall protrude beyond the fa

Seite 27

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace33INSTALLATION10) Close screen doors.8) Slide the Top Grill into the louver brackets located o

Seite 28

34Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATION4-7/16"Openings forelectrical connectionsPower INMillivolt Wires5-1/2"1

Seite 29

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace35INSTALLATIONFor PROPANE Units and Units Equipped with DC Spark Boxes

Seite 30

36Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace36OPERATING INSTRUCTIONSOPTIONAL WALL THERMOSTAT A wall thermostat may be installed if desire

Seite 31

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace3737INSTALLATIONOPERATING INSTRUCTIONSCOPY OF THE LIGHTING PLATE INSTRUCTIONS1) Push in gas co

Seite 32

38Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceMAINTENANCEfrom "PILOT" to "OFF" unless knob is pushed in slightly. Do no

Seite 33

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace39MAINTENANCEWARNINGThe use of substitute glass will void all product warranties.Do not operate

Seite 34

4Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceTABLE OF CONTENTSWiring Diagrams ...34O

Seite 35

40Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceMAINTENANCEREMOVING VALVE1) Shut off the gas supply.2) Remove the louvers (and bay door if

Seite 36 - OPERATING INSTRUCTIONS

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace41MAINTENANCEINSTALLING VALVE8) Reinstall the 12 hold down screws.9) Hook up the 2 TP and 2 T

Seite 37

42Regency® P42-4 Zero Clearance Direct Vent Gas FireplacePARTS LISTP42 MAIN ASSEMBLY Part # Description Part #

Seite 38 - MAINTENANCE

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace43PARTS LISTP42 BURNER & LOG ASSEMBLY Part # Description

Seite 39

44Regency® P42-4 Zero Clearance Direct Vent Gas FireplacePARTS LISTP42 FLUSH DOOR & LOUVERS Part # Description 600-960 Flush

Seite 40

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace45PARTS LISTP42 BAY FRONT & LOUVERS 603-930 Bay Front Complete with Glass & Black Tri

Seite 41

46Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceNOTES

Seite 42 - PARTS LIST

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace47WARRANTYRegency® Fireplace Products are designed with reliability and simplicity in mind. In

Seite 43

Installer: Please complete the following informationDealer Name & Address: _______________________________________________________________________

Seite 44

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace5SAFETY LABELThis is a copy of the label that accompanies each P42 Zero Clearance Direct Vent G

Seite 45

6Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceREQUIREMENTS5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the followin

Seite 46

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace7INSTALLATIONBEFORE YOU STARTSafe installation and operation of this appliance requires common

Seite 47 - WARRANTY

8Regency® P42-4 Zero Clearance Direct Vent Gas FireplaceINSTALLATIONINSTALLATION CHECKLIST1) Locate appliance, refer to the following sections: a)

Seite 48

Regency® P42-4 Zero Clearance Direct Vent Gas Fireplace9INSTALLATIONDiagram 1UNIT SPECIFICATIONSThis includes:1) Clocking the appliance to ensure the

Kommentare zu diesen Handbüchern