Freestanding Gas Fire
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
Owners &
Installation
Manual
LISTINGS AND CODE APPROVALS
These gas appliances have been
tested in accordance with AG 103,
NZS 5262 and have been certified by
the Australian Gas Association for
installation and operation as
described in these Installation and
Operating Instructions.
Your unit should be serviced
annually by an authorised service
person.
Models: F37-NG
F37-LPG
01/20/04
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any
phone in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your
gas supplier, call the fire
department.
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional infor-
mation consult an authorized installer, serv-
ice agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flamma-
ble vapours and liquids in the vicinity of this
or any other appliance.
Installation and service must be performed
by an authorized installer, service agency or
the gas supplier.
918-080b
Australia
P.O. Box 533
Braeside, Victoria 3195
New Zealand
1-37 Mt Wellington Hwy.Panmure,
P.O. Box 14349
Auckland 6.
Geneva
Seitenansicht 0
1 2 3 4 5 6 ... 27 28

Inhaltsverzeichnis

Seite 1 - Freestanding Gas Fire

Freestanding Gas FirePLEASE KEEP THESE INSTRUCTIONSFOR FUTURE REFERENCEOwners &InstallationManualLISTINGS AND CODE APPROVALSThese gas appliances h

Seite 2

10 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterSystem Data - F37Burner Inlet Orifice Sizes: NG LPGBurner

Seite 3 - TABLE OF CONTENTS

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 11INSTALLATIONInstaller Notice:These instructions must be leftwith the appliance.Burner Ori

Seite 4 - DATA PLATE

12 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterINSTALLATIONC)02-44AERATIONADJUSTMENTThe burner aeration is factory set but may needadjus

Seite 5

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 13Diagram 2Diagram 34) The latches should already be at theproper setting. If they are too

Seite 6

14 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterINSTALLATIONOPTIONAL WALLTHERMOSTATA wall thermostat may be installed if desired.Connect

Seite 7

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 15WARNING: Electrical Grounding InstructionsThis appliance is equipped with a three pronged

Seite 8

16 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterOPERATING INSTRUCTIONSOPERATINGINSTRUCTIONS1) Read and understand these instructionsbefor

Seite 9

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 17COPY OF THE LIGHTING PLATE INSTRUCTIONSOPERATING INSTRUCTIONSFOR YOUR SAFETY READ BEFORE

Seite 10 - INSTALLATION

18 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterMAINTENANCETROL SYSTEM AND ANY GAS CON-TROL WHICH HAS BEEN UNDERWATER.CAUTION: ANY SAFETY

Seite 11

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 19LATCH ADJUSTMENTThe door latch may require adjustment as thedoor gasket material compress

Seite 12

2 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterTo the New Owner:Congratulations! You are the owner of a state-of-the-art Masport Rear Fl

Seite 13

20 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterMAINTENANCEREMOVING VALVEIf your valve requires maintenance or replace-ment, use the fol

Seite 14

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 214) Remove the two outside frame pieces byremoving two screws per side. See dia-gram belo

Seite 15

22 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterPARTS LIST1) 560-920 Louvre Assy (Set) - Gold560-922 Louvre Assy (Set) - Black4) 730-038

Seite 16 - OPERATING INSTRUCTIONS

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 23F37 BURNER & LOG ASSEMBLY54) 910-373 588412 Knob - Pilot Valve Extension55) 910-372 5

Seite 17

24 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterF37 DOOR ASSEMBLIESPARTS LIST Part#: Aust. New Zealand Description730-924 Gold Mitre

Seite 18 - MAINTENANCE

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 25_________________________________________________________________________________________

Seite 19

26 F37 Masport Rear Flued Room Sealed Freestanding Gas Heater_________________________________________________________________________________________

Seite 20

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 27WARRANTYTHE MASPORT EXPRESS WARRANTYAll new Masport Gas appliances are warranted, subject

Seite 21

Printed in Canada© Copyright 2004, FPI Fireplace Products International Ltd. All rights reserved.

Seite 22 - PARTS LIST

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 3TABLE OF CONTENTS Page PageOperating InstructionsOperating Instructions ...

Seite 23

4 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterThis is a copy of the label that accompanieseach MASPORT Rear Flued Room Sealed Free-stand

Seite 24

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 5INSTALLATION AND REPAIRSSHOULD BE DONE BY AN AUTHOR-IZED SERVICE PERSON. THIS AP-PLIANCE S

Seite 25

6 F37 Masport Rear Flued Room Sealed Freestanding Gas Heater14)Under no circumstances should any solidfuels (wood, paper, cardboard, coal, etc.)be use

Seite 26

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 7INSTALLATIONEXTERIOR FLUE TERMINATION LOCATIONSMinimum clearances required for balanced fl

Seite 27 - WARRANTY

8 F37 Masport Rear Flued Room Sealed Freestanding Gas HeaterPLANNING YOUR FLUEING INSTALLATIONINSTALLATIONFLUEINGThe Horizontal Termination Kit inclu

Seite 28 - Printed in Canada

F37 Masport Rear Flued Room Sealed Freestanding Gas Heater 9INSTALLATIONFLUEING ARRANGEMENTS - VERTICAL TERMINATIONSFOR BOTH RESIDENTIAL & MANUFAC