Regency Liberty L965E Large Gas Fireplace Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Heizkörper Regency Liberty L965E Large Gas Fireplace herunter. Regency Liberty L965E Large Gas Fireplace User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
919-088
04/04/12
Owners &
Installation Manual
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
MODELS: L965E-NG L965E-LP HZ965E-NG HZ965E-LP
www.regency-re.com
Regency L965E / HZ965E
Gas Fireplace
Seitenansicht 0
1 2 3 4 5 6 ... 67 68

Inhaltsverzeichnis

Seite 1 - Gas Fireplace

WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal i

Seite 2 - WARNING!

Figure 10. Typical Framing for Corner - Detailed.44-3/4"(1137mm)Minimum52-5/16"(1329mm)Minimum toHeader/ShelfHeight from Baseof UnitWall Th

Seite 3 - TABLE OF CONTENTS

201264810014Non-combustibleFacingTo UnitBase18-1/2”33-1/4”102026Top ofFireplaceOpening10" (254mm)No MantelHereFigure 11. Mantel ClearancesFigure

Seite 4 - REQUIREMENTS

Figure 14. Typical Framing for a Raised Hearth - Detailed.TYPICAL FRAMING - RAISED HEARTH:Warning: Failure to follow these guidelines may result in

Seite 5 - DIMENSIONS

Figure 16. Typical Facing for the Fireplace - General.Stone FacingStandardWall BoardHearthFireplaceDoorNon-CombustibleFacing (Supplied)MantelThere ar

Seite 6 - SAFETY LABEL

Receiver CoverReceiverWall StudElectrical Box(Supplied)Figure 22. Receiver Installation.The Receiver is the heart of the remote control system. You n

Seite 7

Table 1: Vent Restrictor Sizes.% RestrictionØ of Flue Restrictor 40%3.878”(98.5mm)50%3.540”(89.9mm)60%3.166”(80.4mm)70%2.742”(69.6mm)80%2.239”(56.9mm

Seite 8

16Figure 24. Vent Termination Restrictions, refer to Table 2.AADELBCFBBBJMKGHIOpenableFixedClosedOpenableFixedClosedTermination CapAir Supply InletGa

Seite 9

16APPROVED VENT PARTS:Table 3: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS).Part DescriptionSimpson Duravent Security Ch

Seite 10 - INSTALLATION

Table 4: Approved Vent ManufacturersManufacturer Trade Name Nominal SizesAmerican Metal Products AmeriVent Direct5” x 8”Security Chimneys Internationa

Seite 11

Figure 27: Installation of TV Above the Unit.TV INSTALLATION ABOVE UNIT:During the development of the L965E/HZ965E, we took into consideration that in

Seite 12

FOR SAFE INSTALLATION AND OPERATION OF YOUR “Regency” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION:• All Regency gas-fired appliances m

Seite 13

QUALIFIED INSTALLERS ONLYPLANNING YOUR INSTALLATION:Prior to starting your venting installation, refer to the section on Allowable Vent Configurations

Seite 14

INSTALLATION OF NON-COMBUSTIBLE WALL AND HEARTH BOARD:Install the non-combustible wall board and hearth protector provided with the unit. The side boa

Seite 15

WARNING• Always maintain required clearances (air spaces) to nearby combustibles to prevent a fire hazard. Do not fill air spaces with insulation. Unle

Seite 16

11/4”(32mm)Figure 39: Installation of Wall Firestop.Figure 38: Installation of Vent Pipe to Termination.Figure 40: Installation of Ceiling Firestop.Fi

Seite 17

Figure 42: Installation of Flashing & Vertical Termination.Figure 41: Vertical Installation Using High Wind Cap.Ceiling FirestopNailsFigure 43: In

Seite 18

Table 5: Minimum ‘H’ for Figure 44.Roof Pitch Minimum Height (H)Feet MetersFlat to 7/12 1 0.3Over 7/12 to 8/12 1.5 0.46Over 8/12 to 9/12 2 0.61Over 9/

Seite 19

Figure 1: Heat Distribution Kit’s Parts Diagram.Please ensure that your Heat Distribution Kit has not been damaged.IMPORTANT: When installing the Heat

Seite 20

4. With the “fIgure 5: fan housIng overall DImensIons.” and “fIgure 6: mInImum InstallatIon clearances for fan.” Cut a opening for the fan in the wal

Seite 21

83/4"(222mm)143/8" (365mm)Fan Grille(Not Supplied)Fan BezelFan HousingStrain ReliefGroundCover PlateFan HousingFigure 8: Wiring fan.e) Secur

Seite 22

**52 5/16"(1329mm)to HeaderAA90"(2286mm)to InternalCeiling60"(1524mm)Chase Minimum Width44 3/4"(1137mm)Minimum26 1/2"(610mm)C

Seite 23

Dimensions: 5Rating Label Location: 5Copy of the safety label 6INSTALLATION 7Introduction: 7Non-Comb

Seite 24

Figure 1: Power Vent Kit’s Parts Diagram.Please ensure that your Power Vent Kit has not been damaged.1. Plan out the venting and wiring installation.

Seite 25

• 50 feet (15.25m) of cable is supplied with this kit, if more venting is required, use 50-2104 - 100 feet (30.5m) PVK CABLE and connect it as shown

Seite 26

Figure 8: Install the power vent.Direct VentPipeOuter ThimblePower VentElectrical CordScrewPower VentAssemblyVacuum SwitchStrain ReliefGreen/GroundWir

Seite 27

Power Vent Case CoverPower VentScrewVacuum SwitchPower Vent AssemblyExhaust Cut-OutFigure 11: Install the power vent cover case.Figure 12: Cover is i

Seite 28

b) Disconnect the connection to the Standing Pilot Switch as shown in Figure 14.c) Disconnect the TH wires from under the valve and plug in the

Seite 29

SILICONE THESE AREASSILICONE THESE AREASSILICONE NOTES: Installer should apply outdoor silicone to the powervent cover on the areas shown below as a

Seite 30

CN1 Molex 9 ways female connector12 3 4 5 6 7 8 9ISPilotSIT 880 ValvePMBLOWERCoaxial femaleDC receptacleMolex Mini-fit 2PCBSIT - DFCCN1S-ReceiverFan C

Seite 31

Figure 19. Vent Termination Restrictions, refer to Table 1.AADELBCFBBBJMKGHIOpenableFixedClosedOpenableFixedClosedTermination CapAir Supply InletGas

Seite 32

DOOR REMOVAL AND INSTALLATION:1) The fireplace door hangs on two (2) hooks on the top of the firebox. The two (2) door latches at the bottom of the fire

Seite 33

Figure 51: Location of Electrical Hook-Up. GAS HOOK-UP:The L965E/H965E are equipped from the factory with a 1/2” SAE 45º male gas fitting. This fittin

Seite 34

DIRECT VENT ONLY: This type is identified by the prefix DV. This appliance draws all of its air for combustion from outside the dwelling, through a spec

Seite 35

LeftRightFigure 53: Removing the Pilot Orifice. Figure 54: Identifying the Orifice. Figure 55: Removing the Gas Orifices. LP GAS CONVERSION:Figure 52: Re

Seite 36

9. Install the correct orifice and replace the pilot hood. The pilot hood has an indexing notch which must be align with the pilot base. E

Seite 37

24. Fire the unit to ensure correct operation and flame picture. Ensure the Split Valve and Flame Modulation works as described in

Seite 38

GLASS BURNER REMOVAL/INSTALLATION:1) Removal the front panel of the burner by removing 2 screws in the locations shown in Figure 61 and Figure 62.4)

Seite 39

GLASS CRYSTAL / STONES INSTALLATION :BURNER PACKAGESUnit *Glass Crystals **Ceramic Spa Stones Volcanic stonesHZ965 12 lbs 140 spa s

Seite 40

REFLECTIVE PANEL INSTALLATION / REMOVAL:1. Install the Rear Porcelain Panel by placing it behind the burner. Use cau-tion- do not scratch the panel.

Seite 41

LOG BURNER / EMBER BED REMOVAL / INSTALLATION:1. Pull the burner away from the mixing tubes.2. Lift the burner up and out of the unit.3. Reverse st

Seite 42

BRICK PANEL INSTALLATION / REMOVAL:919-129a04/03/12 Loosen screws securing Brick Panel Clip shown in Figure 76 and slide Clip away from wall

Seite 43

Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can int

Seite 44

FFGH6) Identify locator on Log D and opposing Locator on Log B as shown in Figure 91. Place Log D gently on Log B.7) Identify locator on Log

Seite 45

52-5/16"(1329mm)5-1/4"(133mm)18-3/4"(476mm)RATING LABEL LOCATION:Figure 1. Dimensions of the Firebox.The Rating and Lighting instructi

Seite 46

WallOptional Front5/8” (16mm) gap betweenthe face & wall(refer to Installation ofFireplace Facing)Figure 96: Optional Front Installed.Figure 97: L

Seite 47

Figure 96: Optional Front Installed.Finishing trim is supplied with the unit for use if the unit is installed up from floor level.The trim will cover t

Seite 48

START-UP & OPERATIONNORMAL SOUNDS DURING OPERATION:Table 1: Normal SoundsComponent Sound & ReasonFascia Creaking when heating up or cooling do

Seite 49

TRANSMITTER (Remote Control with LCD Display)The Proflame Transmitter uses a streamline design with a simple button layout and informative LCD disp

Seite 50

Wall PlateSliderSwitchReceiverJ-BoxWALL MOUNTING THE RECEIVER:The receiver can be placed inside a standard Junction type wall box either by itself or

Seite 51

SMART THERMOSTAT (TRANSMITTER OPERATION) The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point t

Seite 52 - OPERATING INSTRUCTIONS

Figure 112: Remote Control with Aux for Accent Lights.KEY LOCKThis function will lock the keys to avoid unsupervised operation. To activate this funct

Seite 53 - Split Flow

AIR SHUTTER ADJUSTMENT:The L965E/ HZ965E is setup to work with two (2) gas orifices. The orifice on the left (looking from the front) feeds the front bu

Seite 54 - Receiver

WIRING HARNESSCaution: Label all wires prior to disconnection when servicing controls, Wiring errors can cause improper and dangerous operation. Verif

Seite 55

LIGHTING INSTRUCTION LABEL:Figure 117 Lighting Label.CAUTION:Hot while operating. Do not touch. Severe burns may result. Keep children, clothing, fu

Seite 56 - The System For The First Time

Figure 3. Rating Label.ELECTRICAL RATING:(EXIGENCES ÉLECTRIQUES) Fan type circulator (Ventilateur circulaire): 120V AC 60hz/ Less than 7AmpCLEARANCE

Seite 57

LIGHT BULB REPLACEMENTThe L965 comes with 2 accent lights in the rear of the fireplace. These are halogen lights that will need replacing from time to

Seite 58 - MAINTENANCE

TROUBLESHOOTINGProblem Possible Cause SolutionThermostat does not workThe pilot flame has gone out· Turn it ONThe On/Off switch is turn to OFFThe therm

Seite 59 - CAUTION:

TROUBLESHOOTINGProblem Possible Cause SolutionLocking conditionsReset the Proflame DFC board· Turn the system off by pressing the ON/OFF button on the

Seite 60

APPENDIX A - OPTIONAL REDUCED CEILING HEIGHT INSTALLATIONThe L965E/HZ965E can be installed with the reduced ceiling height as shown in this diagram. I

Seite 61

64Regency L965E / HZ965E Gas FireplacePARTS LIST

Seite 62

Item Part Description1 50-2002 Glass Door Assembly2 50-2001 Door Tool3 706-908 Panel Set - Porcelain5 706-902 Brick Panel Set - Old town red706-904 Br

Seite 63 - (1329mm)

WarrantyRegency Fireplace Products is the manufacturer of the Regency line of heating products. At Regency, our commitment to the highest level of qu

Seite 64 - PARTS LIST

12. The Limited Warranty is void if: a) The stove has been operated in atmospheres contaminated by chlorine, fl uorine or other damaging chemicals. b

Seite 65

Printed in Canada© Copyright 2012, FPI Fireplace Products International Ltd. All rights reserved.Installer: Please complete the following informationD

Seite 66 - Warranty

PLANNING YOUR INSTALLATIONINTRODUCTION:This section of the technical manual is for the use of qualified technicians only. Fireplace placement, hearths,

Seite 67

Figure 6. Typical Framing for Internal Chase - Detailed.63"(1600mm)to centerline24"(610mm)Min. Chase Depth52-5/16"(1329mm)Minimum52-5/

Seite 68 - warranty online

Hearth ProtectorFigure 7. Typical Framing for External Chase - General.Figure 8. Typical Framing for External Chase - Detailed.63"(1600mm)to ce

Kommentare zu diesen Handbüchern