P40 Direct Vent Gas Fireplace
Model P40-NG1 P40-LP1
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa)
Manifold Pressure - High 3.5” W.C. (0.87 kPa) 10” W.C. (2.49 kPa)
Manifold Pressure - Low 1.6” W.C. (0.39 kPa) 3.6” W.C. (0.89 kPa)
Orifi ce Size - Front Burner #44 DMS #55 DMS
Orifi ce Size - Rear Burner #35 DMS #53 DMS
Minimum Input 13,000 BTU/h (3.81 kW) 12,000 BTU/h (3.51 kW)
Maximum Input 45,000 BTU/h (13.19 kW) 43,000 BTU/h (12.60 kW)
Vent Sizing 5” Inner / 8” Outer 5” Inner / 8” Outer
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Dura-Vent® Direct Vent GS
Selkirk Direct-Temp
A
B
A
D
C
F
E
Unit Dimensions Description P40
A Front Face Width 40” (1016mm)
B Rear Firebox Width 33-7/16” (889mm)
C Front Face Height 34” (864mm)
D Height w/ Standoff 42-1/2” (1080mm)
E Unit Depth 20-1/16” (508mm)
F Height to Vent 35-1/4” (826mm)
Framing Dimensions Description P40
G Framing Width 40-1/2” (1029mm)
H
*** Framing Height*** 42-1/2” (1080mm)*** + Hearth
I Framing Depth 20-1/16” (508mm)
J Corner Wall Length 50-5/8” (1286mm)
K Corner Facing Wall Width 71-5/8” (1524mm)
L Minimum Height to Combustibles 51-7/8” (1318mm)
M Vent Centerline Height 45-3/8” (1153mm)
N Non-Combustible Facing Height 10-1/4” (260mm)
O Gas Connection Height 1-1/2” (38mm)
P Gas Connection Inset 4-3/4” (121mm)
Q Gas Connection Width 3-1/4” (102mm)
***
Important: Framing height requires consideration of the hearth
depth. Dimension H = H + the thickness of installed hearth.
G
H
I
K
J
L
P
Q
O
M
11" (279mm)
dia. Hole through
wall Vent.
Opening for gas
connection
Top Header
(non-combustible)
Drywall
(or other
facing)
N
Top Header
(non-combustible)
Non-Combustible Facing
P40 Gas Fireplace
Please refer to Page 11 (Exterior Vent Terminations)
for additional guidelines on vent locations.
Unit requires
120V to operate. See
“Wiring Diagram,” on page 17,
for more details. Receptacle is
included with manual.
45June 2007 Regency Product Specifi cations Book
Gas Fireplaces
Gas Fireplaces
Seitenansicht 0
1 2 3 4 5 6 7

Inhaltsverzeichnis

Seite 1 - Gas Fireplaces

P40 Direct Vent Gas FireplaceModel P40-NG1 P40-LP1Fuel Type Natural Gas PropaneMinimum Supply Pressure 5” W.C. (1.25 kPa) 12” W.C. (3.00 kPa)Manifold

Seite 2

Framing and Finishing1) Frame the enclosure for the unit with framing material. Use the determined total thickness of facing material (e.g. drywall

Seite 3

8" dia.Flue pipe5” dia. flue pipespring spacer(Part# 946-623/P)AstroCap XLWall Thimble(required in Canada only)Vinyl SidingStandoffRegency Direct

Seite 4

Rigid Pipe VentingHorizontal or Vertical TerminationsVenting Arrangements - Vertical TerminationsRigid Pipe System(Propane & Natural Gas)Two 45°

Seite 5

Vertical Ventingwith Two (2) 90° ElbowsTwo 45° elbows = One 90° elbowOption V H V+ V1 Maximum total pipe: length, of all sections, must not exceed 30

Seite 6

201012 2046 14245-3/8”(1143mm)MinimumHeightRequirement41268 16810 18Vertical Height (Feet)Horizontal (Feet)Vent Restrictoron Set 1Vent RestrictorFacto

Seite 7

Horizontal Venting with Two (2) 90° Elbows Two 45° elbows = One 90° elbowOption V H+ H1 Maximum total pipe: length, of all sections, must not exceed 3

Kommentare zu diesen Handbüchern

Keine Kommentare